10.1 Error and diagnostics messages
Error code
Error message
(%c)
(%s)
4721
Verification failed in step n: Cell size is smaller
than the specified Min.X Dim.
4722
Verification failed in step n: Cell size is larger than
the specified Max.X Dim.
5000
Not enough resources to process step n
5001
No objects found in step n
10.1.5

Filter error messages

If a filter error occurs, the following error messages are output. You can find additional
information in the section "Overall result" of the online help.
Table 10- 4
Error message
(%s)
Symbol does not use GS1-
encoding
"[Number]" is no valid GS1 Ap-
plication Identifier
GS1 Application Identifier
"[Number]" not found in symbol
content
Symbol content shorter than
given "start position"
ID or separator not found in
symbol content
184
Filter error messages
For filter mode only
GS1
GS1
GS1
Position
ID
Description
During verification, a cell size was measured that is
less than the minimum X-dimension setting (only for
verification according to ISO/IEC 29158).
During verification, a cell size was measured that is
greater than the maximum X-dimension setting (only
for verification according to ISO/IEC 29158).
Step #n could not be executed due to a lack of re-
sources (memory).
Locator: No objects were found in step #n.
Description
The code read does not begin with the GS1
start symbol "]d2".
The string selected in the "Filter ID" box
contains an invalid application identifier tag.
An application identifier specified in the
"Filter ID" box was not found in the read
code.
The read code is shorter than the selected
"Start position"
An ID (field: "Filter ID") or a separator
character (field: "Separators") was not
found in the read code.