Result Evaluation Of A Command - Siemens SIMATIC MV550 S Operating Instructions Manual

Table of Contents

Advertisement

9.3.2.5

Result evaluation of a command

The result of processing a command is indicated by the output double word "STATUS".
In addition to the description in the relevant function manuals of the Ident profile, the
following values have a specific meaning for the optical reader:
Table 9- 31
STATUS
0xE1FE03
0xE6FE01
0xE6FE03
SIMATIC MV500
Operating Instructions, 05/2019, C79000-G8976-C494-02
Result processing in the Ident profile
Meaning
Bad parameter in MV command
Command is incorrectly structured, for example:
The specified address for a "WRITE" command is ≠ "0x0000".
MV command program change
Length of the data to be written is > "0x01".
Program number transferred is > "0x0F".
Program number transferred is not saved.
Command not allowed (see section "Preconditions for the commands
(Page 124)") or the command was aborted.
The precise error message can be obtained with "INIT" without program
selection. Possible causes:
The send buffer is full.
Program corrupted.
Ethernet interface is in operation and there is a problem.
The connected external ring light or power supply is overloaded.
Match string access if there is no match parameter assignment (") in the
program.
Initialization with program selection (init_run/INIT) is not possible:
Program number transferred is not saved.
Optical reader is still in self-test.
Process interfacing via an automation system (PLC, PC)