1.2 Product characteristics

Communication interfaces
The optical readers have all the conventional communications interfaces of industrial
sensors and can therefore be connected to a wide variety of systems. Through the
communications module interface, they can also be seamlessly combined with the
communications modules (ASM/CM), for example, via PROFIBUS.
Simple operation and commissioning
The optical readers are particularly easy to use and commission, despite the wide variety of
possible applications. For most applications, the parameters are set automatically. If,
however, readjustment becomes necessary, the parameters can be assigned using the
integrated Web server and an Internet browser without prior software installation.
1.2
Product characteristics
The optical reader is a compact camera system with an integrated processing unit for
industrial applications with the following product characteristics:
Reading code
● For codes with maximum quality, the read reliability for data matrix code is 99.999 %
(compare quality grading).
● Maximum reading speed of 100 reads per second (Rps) with SIMATIC MV500 S
● A variable object distance is possible (software controlled) when using EF lenses
● Object speed up to 10 m/s
● Code sizes (example: DMC) from 1 mm
● Auto-trigger and scan mode
● Up to 15 parameter sets and code reading settings can be saved and selected.
● Up to 150 codes can be read per image acquisition (SIMATIC MV500 U/X)
● Code verification according to ISO/IEC 16022
Integrated communications interfaces
● Ethernet 10/100/1000 Mbps for TCP/IP and PROFINET IO depending on the device
version
● 1 trigger input and 1 flash output
– Response time of the trigger input: 50-70 us
– Jitter (fluctuation of response time): max. 40 ns
Incoming triggers during a running image acquisition do not interrupt it. Triggers that are
incoming during an image acquisition are handled as NOK processing procedures and
included in the processing statistics.
● Communication module interface
14