Siemens SIMATIC MV550 S Operating Instructions Manual page 177

Table of Contents

Advertisement

Error
Value
message
Onboard
PROFINET
Transfer error
W#16#5007
archiving/
MMI
Transfer error
W#16#5007
PROFINET
IO
Transfer error
W#16#5007
CM/
PROFINET
IO
Program
W#16#5011
requires
EF lens
Save pro-
W#16#500A
gram
Match error
W#16#500B
Timeout
W#16#500D
during saving
TCP commu-
W#16#500E
nication
SIMATIC MV500
Operating Instructions, 05/2019, C79000-G8976-C494-02
Value
Value
TCP/IP
Ident
and
profile,
RS232
STATUS
byte
07
E1FE04
07
E1FE04
07
E1FE04
17
E1FE06
10
E6FE04
11
E1FE07
13
E6FE04
14
E1FE01
10.1 Error and diagnostics messages
Description
The send buffer is full be-
cause the data cannot be
sent in an adequately short
time or the server is not
confirming receipt of the
data in time.
The send buffer is full be-
cause the data cannot be
queried in an adequately
short time.
The send buffer is full be-
cause the data cannot be
queried in an adequately
short time.
An EF lens is configured in
the program but it is not
connected.
The program could not be
created.
The program could not be
created due to faulty match
settings.
The "Save program" process
was canceled because it
took too long.
Connection error in commu-
nication over a TCP connec-
tion or when using an
Ethernet RS-232 converter:
There is no TCP connection
or the data transfer cannot
be completed within the set
time limit.
Service and maintenance
Corrective measures
Reduce the trigger frequency or
reduce the amount of diagnostic
data to be archived. Process the
results on the server side faster.
A high load on the network to
which the optical reader is con-
nected can also block the trans-
fer of the data. If necessary,
check the network connection.
Reduce the trigger frequency or
process the results faster. If
necessary, change the update
time in the PROFINET configu-
ration.
Reduce the trigger frequency or
process the results more quickly
on the CPU. The transmission
speed of the communication
module connection can possibly
be increased.
To cover short-term peak loads,
the size of the image buffer in
the WBM can be increased un-
der"Program > Image acquisition
> Mode".
Reconnect the EF lens or
change the parameter assign-
ment of the program.
Adapt the parameter assign-
ment, the placement of test
objects in the image or the im-
age quality.
Adapt the match settings or use
a suitable test object.
Check the program settings and
start the "Save program" pro-
cess via the WBM, if necessary.
Make sure that the connected
TCP partner is correctly config-
ured and ready to receive.
177