Siemens SIMATIC MV550 S Operating Instructions Manual page 117

Table of Contents

Advertisement

Table 9- 18
Parameter
CMD
OFFSETBUFFER
EPCID_UID
LEN_DATA
ADDR_TAG
Table 9- 19
Address
0x0000
Command: Reset DISA bit
The command data to be "written" in the "PHYSICAL WRITE" command only contains the
command identifier "Reset DISA bit".
If the "DISA" bit of the optical reader has been reset, the command receives positive
acknowledgment. If it was already reset, this command has no effect but is nevertheless
positively acknowledged.
The "PHYSICAL WRITE" command must specify the length "0x01" ("CMD_STRUCT.Length
= 0x01"); otherwise, the command receives a negative acknowledgment.
Table 9- 20
Parameter
CMD
OffsetBuffer
UID
Length
StartAddress
Table 9- 21
Address
0x0000
SIMATIC MV500
Operating Instructions, 05/2019, C79000-G8976-C494-02
CMD_STRUCT
Value
0x71
0x00
0x00
0x01
0x00
Memory area of the receive data (TXREF or RXREF)
Value
0x05
CMD_STRUCT
Value
0x71
0x00
0x00
0x01
0x00
Memory area of the receive data (TXREF or RXREF)
Value
0x06
Process interfacing via an automation system (PLC, PC)
Meaning
Command identifier
"Set DISA bit"
Meaning
Command identifier
"Reset DISA bit"
9.3 Control with Ident profile
117