Ram Pressure Relief Procedure - Graco Therm-O-Flow 20 EasyKey Instructions Manual

Hot melt pail unloaders
Table of Contents

Advertisement

Operation

Ram Pressure Relief Procedure

Follow Pressure Relief Procedure when you stop
spraying and before cleaning, checking, servicing, or
transporting equipment.
To relieve air pressure in the ram:
1. Relieve the supply unit pressure, see page 27.
2. Place the ram UP/DOWN lever in the DOWN posi-
tion. Move the ram to the DOWN position.
3. When the ram reaches the full down position, place
the ram UP/DOWN lever in the center position (off).
4. Close the system bleed-type master air valve (A).
28
TI8141A
A
TI8135A
5. Exhaust air from both sides of the ram:
a. Move the ram UP/DOWN lever to the DOWN
position until all air is exhausted from one side
of the ram.
b. Move the ram UP/DOWN lever to the UP posi-
tion until all air is exhausted from the other side
of the ram.
TI8141A
TI8141A
312094K

Advertisement

Table of Contents
loading

Table of Contents