Setup

1.
Locate Reactor
a.
Locate Reactor on a level surface. See
Dimensions, page 36, for clearance
and mounting hole dimensions.
b.
Do not expose Reactor to rain.
CAUTION
Bolt Reactor to original shipping pallet before lifting.
c.
Use the casters to move Reactor to a
fixed location, or bolt to shipping pallet
and move with forklift.
d.
To mount on a truck bed or trailer,
remove casters and bolt directly to truck
or trailer bed. See page 36.
2.
Electrical requirements
See T
1.
ABLE
Installing this equipment requires access to parts
which may cause electric shock or other serious
injury if work is not performed properly. Have a quali-
fied electrician connect power and ground to main
power switch terminals, see page 17. Be sure your
installation complies with all National, State and Local
safety and fire codes.
16
Table 1: Electrical Requirements
(kW/Full Load Amps)
Voltage
Part No.
Model
(phase)
253200
H-25
230V (1)
253201
H-25
230V (3)
253202
H-25
380V (3)
253203
H-XP2
230V (1)
253204
H-XP2
230V (3)
253205
H-XP2
380V (3)
253206
H-25
230V (1)
253207
H-25
230V (3)
253208
H-25
380V (3)
253300
H-25
230V (1)
253301
H-25
230V (3)
253302
H-25
380V (3)
253303
H-XP2
230V (1)
253304
H-XP2
230V (3)
253305
H-XP2
380V (3)
253306
H-25
230V (1)
253307
H-25
230V (3)
253308
H-25
380V (3)
* Full load amps with all devices operating at maximum
capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
** Total system watts, based on maximum hose length
for each unit:
Part Nos. 253200 through 253208, 210 ft (64 m)
maximum heated hose length, including whip hose.
Part Nos. 253300 through 253308, 310 ft (94.6 m)
maximum heated hose length, including whip hose.
Setup
Full
Load
Peak
System
Amps*
Watts**
63
14,700
40
14,700
29
14,700
95
22,000
58
22,000
35
22,000
95
22,000
58
22,000
35
22,000
69
15,960
45
15,960
35
15,960
100
23,260
58
23,260
35
23,260
100
23,260
58
23,260
35
23,260
311299C