Panasonic WJ-SX150 Series Addendum page 38

Addendum for system controller wv-cu950/wv-cu650: matrix switcher wj-sx150 series operating procedures
Hide thumbs Also See for WJ-SX150 Series:
Table of Contents

Advertisement

● To Control a Recorder and Cameras via the Network
The following is the description of the connection between a recorder and this unit to control the recorder and cameras via the
network.
1. Set the unit address of the recorder to 5 or larger.
(Refer to the recorder's operating instructions.)
2. Set the [Camera control] setting to "PSD" for all cameras in SETUP MENU of the recorder.
3. Connect the unit's CAM OUT 1 to 16 connectors to the recorder's VIDEO IN 1 to 16 connectors with a coaxial cable.
4. Connect the unit's EXT IN connector to the recorder's MULTISCREEN OUT connector with a coaxial cable.
5. Connect the unit's DATA HDR and DATA4 connectors to the recorder's DATA ports with modular cables.
6. Select the recorder's new unit address, which is set in Step 1, in 600 RECORDER of SETUP MENU or the Recorder window
of WJ-SX150A Administrator Console. (Refer to this unit's operating instructions.)
Notes:
• Select the PS·Data protocol for the DATA 4 setting.
(Refer to this unit's operating instructions.)
• If the recorder's unit address, set in Step 1, and the recorder setting, set in Step 6, are different, the recorder will not be
operable.
• In these connections, you cannot use a PS·Data system controller.
• From system controllers connected to the unit, you cannot control the monitor connected to the MONITOR OUT 1 connec-
tor of recorder.
38
System controller
(Terminal Mode)
ALARM
SERIAL
DATA HDR
DATA 4
DATA 3 DATA 2
TERM
OFF
ON
PS•DATA
RS485(CAMERA)
16
15
14
13
12
11
10
9
8
IN
OUT
16
15
14
13
12
11
10
9
8
CAMERA
DATA HDR
DATA 4
(PS·Data)
MONITOR OUT x
1
3
1
SERIAL
ALARM
CASCADE
4
2
OUT
2
AUDIO IN
AUDIO OUT
MONITOR OUT CASCADE IN
MONITOR (VGA)
ALARM/CONTOROL
16
15
14
13
12
11
10
9
8
IN
OUT
16
15
14
13
12
11
10
9
8
VIDEO
* Set the recorder's unit address to 5 or larger.
** LAN: Local Area Network
Monitor
EXT IN
MONITOR OUT
EXT IN
3
1
SIGNAL GND
(PLAY IN)
CAMERA
RS485(CAMERA)
SW IN
DATA 1
LINE
SELECT
2
4
4
2
EXT OUT
MONITOR OUT
(REC OUT)
7
6
5
4
3
2
1
7
6
5
4
3
2
1
Matrix Switcher
DATA
SIGNAL GND
MODE
COPY 1
2
1
DATA
RS485(CAMERA)
10/100BASE-T
EXT STORAGE
7
6
5
4
3
2
1
7
6
5
4
3
2
1
Recorder*
HUB/Router
POWER
AC IN
POWER
AC IN
LAN**

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-cu650Wv-cu950

Table of Contents