Panasonic WJ-SX550C Operating Instructions Manual page 37

System 500 matrix switcher and system controller
Hide thumbs Also See for WJ-SX550C:
Table of Contents

Advertisement

WV-PB5564 Alarm Board
Appearance
q Alarm Number Display
Indicates the alarm input number when an alarm is received from the associated alarm
sensor.
Note: The display indicator lights up as shown below when the alarm number is over
one hundred.
w Mode Selection Switch (MODE)
2
This rotary switch, in combination with the Test button, is used to select the alarm test
mode.
Mode 0: Press the Test button to receive an alarm number display in chronological
order from the internal memory which stores all alarms received from the Alarm
Input Ports.
Mode 1: Press the Test button to simulate receiving alarm inputs 1-64 in ascending
order, one alarm per second.
Use this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3 setup.
Mode 2: Press the Test button to simulate receiving alarm inputs 1-64 all at the same
time.
Use this mode to test the system for Alarm Mode-1, Mode-2 or Mode-3 setup.
Mode 3-9: These modes are not available.
Note: Alarm inputs 65-128 are activated in the above modes if SW1 on the board is set
to Board Number 2. Refer to the Board Setting on page 41.
e Test Button (TEST)
This button is used to run the alarm test mode in combination with the Mode Selection
Switch.
r Reset Button (RESET)
Resets the alarm test mode or clears alarm records from the internal memory.
39
Indicator
ALARM
q
MODE
5
w
TEST
e
RESET
r
1-32
t
33-64