Omron NX Series User Manual page 86

Machine automation controller
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

6 Device Variables Related to the NX-series EtherNet/IP Unit
Variable name
EIP_Comm1Sta-
CIP Communica-
tus.RegTarget-
tions1 Registered
Sta[255]
Target Node Informa-
tion
EIP_Comm2Sta-
CIP Communica-
tus.RegTarget-
tions2 Registered
Sta[255]
Target Node Informa-
tion
EIP_Comm1Sta-
CIP Communica-
tus.EstbTarget-
tions1 Normal Target
Sta[255]
Node Information
EIP_Comm2Sta-
CIP Communica-
tus.EstbTarget-
tions2 Normal Target
Sta[255]
Node Information
EIP_Comm1Sta-
CIP Communica-
tus.TargetPLCMo-
tions1 Target PLC
deSta[255]
Operating Mode
6-12
Meaning
Gives a list of nodes for which
EtherNet/IP connections are registered
for CIP communications 1.
This variable is valid only when the
EtherNet/IP port is the originator.
Array[x] is TRUE:
The connection to the node with a target
node ID of x is registered.
Array[x] is FALSE:
The connection to the node with a target
node ID of x is not registered.
Gives a list of nodes for which
EtherNet/IP connections are registered
for CIP communications 2.
This variable is valid only when the
EtherNet/IP port is the originator.
Array[x] is TRUE:
The connection to the node with a target
node ID of x is registered.
Array[x] is FALSE:
The connection to the node with a target
node ID of x is not registered.
Gives a list of nodes that have normally
established EtherNet/IP connections for
CIP communications 1.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a target
node ID of x was not established, or an
error occurred.
Gives a list of nodes that have normally
established EtherNet/IP connections for
CIP communications 2.
Array[x] is TRUE:
The connection to the node with a target
node ID of x was established normally.
Array[x] is FALSE:
The connection to the node with a target
node ID of x was not established, or an
error occurred.
Shows the operating status of the target
node Controllers that are connected for
CIP communications 1, with the Ether-
Net/IP port as the originator.
The array elements are valid only when
the corresponding Normal Target Node
Information is TRUE. If the corresponding
Normal Target Node Information is
FALSE, it indicates the previous operat-
ing status.
Array[x] is TRUE:
This is the operating state of the target
Controller with a node address of x.
Array[x] is FALSE:
Other than the above.
Function
Data type
ARRAY
[0..255] OF
BOOL
ARRAY
[0..255] OF
BOOL
ARRAY
[0..255] OF
BOOL
ARRAY
[0..255] OF
BOOL
ARRAY
[0..255] OF
BOOL
NX-series EtherNet/IP Unit User's Manual (W627)
Range of
Reference
values
TRUE or
page 6-25
FALSE
TRUE or
page 6-26
FALSE
TRUE or
page 6-26
FALSE
TRUE or
page 6-26
FALSE
TRUE or
page 6-26
FALSE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-eip201

Table of Contents