The pivot kit is shown in Fig 15 (posts are shown at the top, then back plates and metal
springs at the bottom).
Remove the face seal as described above (M-100/M-200 and M-300 Series only). With
visor in the up position, pull down on metal spring and pull out to remove (Fig 16).
Remove the frame. If replacing frame or pivot kit, remove post with red "3M" from visor
frame by placing the frame on the edge of a table, resting on the post, and press down
forcefully on the visor frame with heel of hand. If replacing pivot kit, lift back plate up
slightly and slide out from slot on headgear shell to remove (Fig 17). Use a tool if
necessary.
The replacement post should be inserted into the frame so the '3M' is positioned the
correct way up when the product is worn. Insert the replacement back plate (round edge
first and with the 'fan' pattern facing to the outside of the helmet - Fig 18). Line up the
visor frame over the attachment slots and slide the spring into place (Fig 19). Note: The
visor frame should be in the fully open or closed position before the spring is installed.
Replacement visor frame buttons.
Follow instructions for visor replacement above and insert replacement buttons.
Visor gasket replacement.
Pull the black visor gasket slowly from the groove (Fig 20). Install the new gasket by
aligning with the edge of the groove. Press the gasket firmly and fully into the groove.
Forehead comfort pad.
Detach the comfort pad from the headband. Wrap the replacement comfort pad around
the headband and re-attach (Fig 21).
Head, neck and shoulder cover (M-100/M-200/M-300 Series only).
Remove the black visor gasket from the groove (Fig 20). Insert headtop into cover and
pull the air inlet fully through the opening in the back of the cover. Insert the gasket on the
cover firmly and fully into the groove on the top of the visor frame.
Flame resistant headtop cover.
Remove the black visor gasket from the groove (Fig 20). Insert the gasket on the cover
firmly and fully into the groove on the top of the visor frame. Pull loop on headtop cover
over the air inlet on the headtop.
The air inlet fits through the hole in the back of the cover. Note: If fitting the cover in
combination with the ear muff assembly, please see the ear muff assembly instructions
below.
Chin strap.
Attach the chin strap to the attachment points on the head suspension (Fig 22).
Headtop mounted ear muff assembly (M-100/M-200/M-300 Series only).
Locate the attachment points (Fig 23 and 24 ). As worn, the right side mount is marked
'X' and the left side mount is marked 'O' (Fig 25). The earmuff should be attached as
shown in Fig 26.
Use a screwdriver to push in the attachment points before screwing the ear muff
assembly as tightly as possible to the shell.
Note: If using the ear muff assembly in combination with the flame resistant headtop
cover, the attached ear muffs must first be pulled through the slits in the headtop cover
before pulling the loop on the cover over the air inlet.

STORAGE AND TRANSPORTATION

These products should be stored in the packaging provided in dry, clean conditions away
from sources of high temperature and petrol and solvent vapours.
^ Do not store in direct sunlight.
Do not store outside the temperature range -30°C to +50°C or with humidity above 90%.
If the product will be stored for an extended period of time before use, the suggested
storage temperature is 4°C to 35°C.
When stored as stated, the maximum life (shelf life plus in-use life) is 5 years from date of
manufacture.
The original packaging is suitable for transporting the product throughout the European
Union.

TECHNICAL SPECIFICATION

(Unless otherwise stated in the Reference Leaflet)
Respiratory Protection
M-100 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Versaflo™ TR-602E, 3M™ Versaflo™
TR-302E/TR-302E+, 3M™ Jupiter™ and 3M™ Adflo™ Powered Air Turbos.
EN14594 2B when connected to 3M™ Versaflo™ V-100E, V-200E, V-500E and 3M™
Flowstream™ Regulators.
EN1835 LDH2 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
M-200 Series
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Jupiter™ Powered Air Turbo.
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-602E and 3M™ Versaflo™
TR-302E/TR-302E+ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators.
M-300 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-602E and 3M™ Versaflo™
TR-302E/TR-302E+ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Jupiter™ and 3M™ Adflo™ Powered Air
Turbos.
EN14594 2B when connected to 3M™ Flowstream™ Regulator.
EN1835 LDH2 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
M-400 Series
Nominal Protection Factor = 10 Assigned Protection Factor = 10
EN12941 TH1 when connected to 3M™ Dustmaster Powered Air Turbo.
Nominal Protection Factor = 50 Assigned Protection Factor = 20
EN12941 TH2 when connected to 3M™ Adflo Powered Air Turbo
Nominal Protection Factor = 500 Assigned Protection Factor = 40
EN12941 TH3 when connected to 3M™ Versaflo™ TR-602E, 3M™ Versaflo™
TR-302E/TR-302E+ and 3M™ Jupiter™ Powered Air Turbos.
Nominal Protection Factor = 200 Assigned Protection Factor = 40
EN14594 3B when connected to 3M™ Versaflo™ V-100E, V-200E and V-500E
Regulators and 3M™ Flowstream™ Regulator.
EN1835 LDH3 when connected to 3M™ Vortemp™ and 3M™ Vortex Regulators.
Note: When regulators and compressed air supply tubes that are exclusively marked
EN1835 are used with M-Series headtops, the system will only meet the requirements of
EN1835.
Note: The M-Series headtops meet the higher strength (B) requirements of EN14594.
They are approved for use with a range of compressed air supply tubes that meet both
the lower and higher strength (A and B) requirements. Please see Equipment Marking
section of relevant Regulator User Instructions for information.
Nominal Protection Factor (NPF) - a number derived from the maximum percentage of
total inward leakage permitted in relevant European Standards for a given class of
respiratory protective devices.
Eye Protection
Visor surround - EN166:3:9:BT (Liquid splash 3, molten metal 9 and medium energy
impact at extremes of temperature BT).
M-925 Visor – EN166:1:BT:3:9 (Optical class 1, medium energy impact at extremes of
temperature BT, liquid splash 3 and molten metal 9)
M-927 Visor – EN166:1:BT:3 (Optical class 1, medium energy impact at extremes of
temperature BT and liquid splash 3).
Head protection
The M-206 and M-207 headtops with M-200 helmet shell meet the requirements of
EN812 (see below). 440 V a.c. - Electrical insulation.
The M-306 and M-307 headtops with M-300 helmet shell meet the requirements of
EN397 (see below).
The M-406 and M-407 headtops with M-400 helmet shell meet the requirements of
EN397 (see below).
LD - Lateral deformation.
440 V a.c. - Electrical insulation.
Flow Characteristics
Manufacturers Minimum Design Flow (MMDF).
170 l/min (3M™ Versaflo™ TR-602E and TR-302E/TR-302E+ Powered Air Turbo and
3M™ Versaflo™ V-100E, V-200E and V-500E Regulators)
160 l/min (3M™ Adflo™ Powered Air Turbo)
150 l/min (3M™ Jupiter™ and Dustmaster™ Powered Air Turbo and 3M™
Flowstream™, 3M™ Vortemp™ and 3M™ Vortex Regulators).
Note: When using the M-400 Series headtops in combination with the 3M™ Vortemp™
and 3M™ Vortex Regulators, the recommended pressure range is 4 - 6 bar).
Maximum Flow - See appropriate User Instructions.
Head Size
Breathing tube lengths
BT-20S – 735mm (29 inches)
BT-20L – 965mm (38 inches)
BT-30 – 525mm to 850mm (21 inches to 34 inches)
BT-40 – 840mm (33 inches)
834008 - 950mm (37 inches)
834016 - 525mm to 850mm (21 inches to 24 inches)
834017 - 775mm (31 inches)
Operating Temperature
-10ºC to +55ºC
Weight:
M-106 605 g, M-107 605 g, M-206 650g, M-207 650g, M-306 873 g, M-307 873 g, M-406
1196 g and M-407 1147 g.