C. Cont. Mode
Calibration
Bline Mode
>
Cont. Mode
Exit
Press the
button to enter the black-mark sensor calibration mode.
C-1 Automatic
When enter the [Automatic] option, you will see following message and printer will
calibrate the sensor sensitivity automatically. When calibration process is completed,
the LCD screen will return to the previous menu.
Cont. Mode
Automatic
C-2 Manual
In case "Automatic" sensor calibration cannot apply to the media, please use
"Manual" function to calibrate the sensor manually.
Cont. Mode
>
When enter [Manual] option, you will see following message. Please complete there
steps:
Cont. Mode
Remove Label
Intensity
Ref. Level
Cont. Mode
Scan Paper
Intensity
Ref. Level
3/4
Cont. Mode
>
Automatic
Manual
Exit
and
buttons to scroll the cursor to the sensor type. Press the
2/3
Automatic
Manual
Exit
xxx
xxx
1/3
1. Remove the continuous label. Press
the
into the printer.
x
2. Then, put the continuous label under
the media sensor. Press the
button to set the value into
the printer.
x
49
button to set the value