AGFA CG Triumvirate TT042-50 Series User Manual page 50

Thermal transfer / direct thermal bar code printer
Table of Contents

Advertisement

A. Gap Mode
Calibration
>
Gap Mode
Bline Mode
Cont. Mode
Press the
button to enter the sensor calibration mode.
Note: If printing from enclosed software/driver, the software/driver will send out the
GAP or BLINE command, which will overwrite the sensor type setting set from
the front panel.
A-1 Automatic
When enter the [Automatic] option, you will see following message, and printer will
feed 2 to 3 gap labels to calibrate the sensor sensitivity automatically. When
calibration is completed, the LCD screen will return to the previous menu.
Gap Mode
Automatic
A-2 Manual
In case "Automatic" sensor calibration cannot apply to the media, please use
"Manual" function to calibrate the gap sensor manually.
Gap Mode
>
When enter [Manual] option, you will see following message. Please complete those
steps:
1/4
Gap Mode
>
and
buttons to scroll the cursor to the media type and press the
2/4
Automatic
Manual
Pre-Printed
Paper Len.
00812 dot
1/4
Automatic
Manual
Pre-Printed
1. Press the
the cursor from left digit to right digit,
and press the
the value from "0" to "9" and the "dot/
mm/ inch". Press the
button to set the paper length into the
printer.
43
button to move
button to set