5
Apply heat to the contraction tube to contract it.
Method 1
Contraction tube
6
Wrap it with the insulation tape twice or more and
position your contraction tube in the middle of the
insulation tape.
Method 1
Insulation tape
40 mm
7
After tube contraction work is completed, wrap it with the
insulation tape to finish.
Three or more layers of insulation are required.
Method 1
IInsulation tape
CAUTION
Make sure that the connection parts are not exposed
to outside.
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials
that have the same level of withstand voltage with
the power cable. (Comply with the local regulations on
extensions.)
WARNING
In case of extending the electric wire, please DO NOT
use a round-shaped Pressing socket.
Incomplete wire connections can cause electric
shock or a fire.
Method 2
Contraction tube
Method 2
Insulation tape
35 mm
Method 2
IInsulation tape
Step 15 Setting the indoor unit
addresses and the installation options
You cannot set both of the indoor unit addresses and the
installation options in a batch: set both of them respectively.
Common steps for setting the addresses
and options
AR-KH**U remote control (for 360 cassette only)
Entering the mode
for setting the
options
Temperature
button
Timer button
NOTE
The remote control display may vary depending on the
model.
1
Enter the mode for setting the options:
a
Remove the batteries from the remote control.
b
While holding down the
(Timer) buttons simultaneously, insert the batteries
into the remote control.
c
Make sure that you are entered to the mode for
setting the options:
Setting the option
values
Mode button
Wheel
(Temp) and
English
23