Safety Information
Installing the unit
WARNING
IMPORTANT: When installing the unit, always remember to
connect first the refrigerant tubes, then the electrical lines.
Always disassemble the electric lines before the
refrigerant tubes.
Upon receipt, inspect the product to verify that it has
not been damaged during transport. If the product
appears damaged, DO NOT INSTALL it and immediately
report the damage to the carrier or retailer (if the
installer or the authorized technician has collected the
material from the retailer.)
After completing the installation, always carry out a
functional test and provide the instructions on how to
operate the air conditioner to the user.
Do not use the air conditioner in environments with
hazardous substances or close to equipment that
release free flames to avoid the occurrence of fires,
explosions or injuries.
Do not install the product in a place where
thermohygrostat is needed (such as server room,
machinery room, computer room, etc.) Those places do
not provide guaranteed operation condition of the product
therefore performance can be poor in these places.
Do not install the product in a ship or a vehicle (such
as a campervan). Salt, vibration or other environmental
factor may cause the product malfunction, electric
shock or fire.
Excessive indoor humidity or clogged condensate drain
lines may cause water to drip from indoor units.
Do not install the indoor unit where dripping could
result in damage to property, such as above electronic
equipment or other sensitive instruments.
Our units should be installed in compliance with the
spaces shown in the installation manual, to ensure
accessibility from both sides and allow repairs or
maintenance operations to be carried out. The
unit's components should be accessible and easy to
disassemble without endangering people and objects.
For this reason, when provisions of the installation
manual are not complied with, the cost required to
access and repair the units (in SAFETY CONDITIONS,
as set out in prevailing regulations) with harnesses,
ladders, scaffolding or any other elevation system will
NOT be considered part of the warranty and will be
charged to the end customer.
4
English
Power supply line, fuse or circuit breaker
WARNING
Always make sure that the power supply is compliant
with current safety standards. Always install the air
conditioner in compliance with current local safety
standards.
Always verify that a suitable grounding connection is
available.
Verify that the voltage and frequency of the power
supply comply with the specifications and that the
installed power is sufficient to ensure the operation of
any other domestic appliance connected to the same
electric lines.
Always verify that the cut-off and protection switches
are suitably dimensioned.
Verify that the air conditioner is connected to the power
supply in accordance with the instructions provided in
the wiring diagram included in the manual.
Always verify that electric connections (cable entry,
section of leads, protections...) are compliant with
the electric specifications and with the instructions
provided in the wiring scheme. Always verify that all
connections comply with the standards applicable to
the installation of air conditioners.
Devices disconnected from the power supply should
be completely disconnected in the condition of
overvoltage category.
Be sure not to perform power cable modification,
extension wiring, and multiple wire connection.
It may cause electric shock or fire due to poor
connection, poor insulation, or current limit
override.
When extension wiring is required due to power
line damage, refer to "Step 14 Optional: Extending
the power cable" in the installation manual.