SIDOOR functions
4.1 Basic functions
Connection
SIDOOR ATD401W:
The "CLOSE DOOR" function is connected to "Input 3" (X6). See also section Digital input signals
(Page 132).
"Main menu → General setup → Special parameters → FBLOCK configuration → Default input"
has to be selected in the control menu so that door commands can be issued via the digital
inputs.
Signals
Signal
1 (voltage applied)
0 (voltage not applied)
4.1.6

DOOR OPEN (command given via digital inputs)

Description of function
The OPEN DOOR command opens the door according to the configured travel curve as long as
the command is present. The door reaches the OPEN position at slow start speed. Then, if the
OPEN DOOR command is present, the door is held open by the torque that can be adjusted by
the parameter "Continuous torque open".
The OPEN DOOR command has priority over all other control commands.
Note
If the commands CLOSE DOOR and OPEN DOOR are present simultaneously, the door always
moves in the OPEN direction.
SIDOOR ATD420W / ATD430W
See also section Free function blocks (FBLOCK) (Page 92).
Note
As an alternative, the signal can also be evaluated via the PLC (process image).
Connection
SIDOOR ATD401W:
The "DOOR OPEN" function is connected to "Input 4" (X6). See also section Digital input signals
(Page 132).
62
Meaning
The CLOSE DOOR command is pending
The CLOSE DOOR command is not pending
ATD4xxW for industrial applications