Failure to comply with these requirements may prevent the correct operation of the stove. Follow all the instructions
presented on the diagrams.
The pellet stove stoves operate with the combustion chamber in vacuum, so it is necessary to have a fume exhaust pipe to
extract combustion gases properly.
All material used to flue the product must comply with current Building regulations.
Insulation: The flue must be double-walled and insulated to make sure that flue gases do not cool down going outwards,
which would cause an inadequate circulation and condensation that may damage the stove.
Windproof terminal: A windproof terminal must always be installed to avoid the backflow of flue gases.
Draught in the chimney. All installation must guarantee a draught of 12 Pa (0.12mbars) measured when hot and at the
maximum power.
7.1.5

Installation with a chimney

If the stove is to be installed in a chimney it must be done so using a flue pipe of appropriate diameter direct to the stove.
Manufacturers recommendation is to install with a flexible flue line of diameter 80-100mm. Maximum height of installation at 80mm
diameter is 8metres.
A T-piece must be installed between the connection pipe and the main part of the chimney to allow for periodic inspection and
annual maintenance. The T-piece will also ensure that any condensation of the chimney gets collected and does not return in the
mechanisms of the stove. The installation must be completed with a windproof and rainproof Hat, recommended for use with pellet
stoves.
7.1.6

Ventilation

Ventilation: The stove must have adequate air for combustion and the room must have adequate air for ventilation, adequate air supply must be
provided in line with building regulations. The Stanley Lir Pellet stove has a circular pipe (40mm) that may be connected to the
exterior of the house. An outside air kit and adaptor from 40-100 is available to order from Waterford Stanley.
This product should not be installed in the same room as an extractor fan. A test should be undertaken where the product
is installed in a room adjacent to a room with an extractor fan verifying that there is enough air flow for the pellet stove to
work properly.
If you do not use the stove for a long time, check it to make sure that the flue pipes are clear before lighting the fire.