Flue/ chimney installation

The appliance must be connected using a connect-
ing pipe of diameter 80mm. . A Tee piece must be
installed at the base of the chimney to allow for
cleaning/ inspection. The main section of the flue
should be installed using a diameter 125mm flue
pipe which must begin within 1.5 metres of the appli-
ance flue outlet
Single wall flue is permitted in the area to be heated,
outside of that area the flue must be insulated.
If the flue is to be routed though an existing
chimney it can be done using a flexible stainless
steel pipe with a register plate at the base of the
chimney , the area in the chimney external to the
flue liner must be back filled with insulation.
Where the flue pipe is installed external to
the dwelling, it must use twin wall insulated stainless
steel flue. The flue must have a vertical length of at
least 2 metres. A horizontal length is not recom-
mended other than at the rear of the appliance, the
horizontal run should be no more than 600mm, on
all other sections of flue it is recommended that they
make an angle to the vertical of no more than 45
degrees.
The flue termination point/outlet must be above roof
level and in accordance with building regulations
part J.
IMPORTANT: All sections of the flue pipe must be
accessible for inspection, and allow for internal
cleaning, removal or replacement.

Electrical connection

Important: The appliance MUST be earthed.
Before installing the appliance, the power supply
system must be checked to ensure it has an effec-
tive earth circuit.
Important: the power supply cable must be of suf-
ficient cross-section for the power requirement of
the appliance.
The supply voltage required for the stove is 220-
240 V at 50 Hz. Voltage variations greater than
10% of the rated value may cause irregular opera-
tion, or damage to the electrical system. The appli-
ance must be positioned so that the domestic
power supply plug remains accessible.
If the power supply cable becomes damaged,
switch off the power and have it repaired by an
authorised Stanley service agent.