Page 1
PLEASE RETAIN Lismore Boiler Solid Fuel Stove INSTALLATION AND OPERATING INSTRUCTIONS This appliance is hot while in operation and retains its heat for a long period of time after use. Children, aged or infirm persons should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled.
All warranty claims must be reported to the Waterford Stanley Service Department and must be submitted with the prod- uct serial number (located on the front casting), date of purchase, proof of purchase (if requested) and details of the specific nature of the problem.
INSTALLATION CHECK LIST Tick Flue System 1. Minimum Flue Height of 4.6 metres (15 feet). 2. Appliance should be connected to a minimum of 1.8 metres (6 feet) of 150mm (6”) flue pipe. 3. The horizontal flue run should not exceed 150mm (6”) 4.
IMPORTANT OPERATION / MAINTENANCE NOTES Now that your Stanley Solid Fuel Stove is installed and no doubt you are looking forward to many comforts it will provide, we would like to give you some tips on how to get the best results from your stove.
1:2007 Design, Installation and Commissioning of When installing, operating and maintaining your chimneys. BS EN 14336:2004: Heating Systems in Lismore Stove respect basic standards of fire safety. Buildings. Installation & Commissioning of Water Read these instructions carefully before commenc- Based Heating Systems.
FLUE EXIT (TOP & REAR) The stove must be connected to a chimney with a minimum continuous draught of 0.06 w.g. Poor draught conditions will result in poor performance. The stove is designed to allow the chimney be cleaned through the stove. If the chimney cannot be All register plates, restricter plates, damper etc., cleaned through the stove it is necessary to provide a soot box/access door in the flue for cleaning.
VENTILATION & COMBUSTION AIR REQUIRE- Fig.4 REAR OUTLET MENTS It is imperative that there is sufficient air supply to the stove in order to support correct combustion. The air supply to this appliance must comply with current Building Regulations Part J, Heat Providing Appliances.
If there is an extraction fan fitted in adjacent rooms As wind effects can create suction and pressure where this appliance is fitted, additional air vents zones on opposite sides of the dwelling it is may be required to alleviate the possibility of recommended to run the air vent from opposite spillage of products of combustion from the appli- poles (North, South, East &...
There are several conditions to be considered in The fitting of a pipe thermostat to the flow pipe is selecting a location for your Stanley Lismore Stove. essential in order to activate the water circulation pump when the water reaches the selected a.
Fig.9 WATER CIRCUIT TEMPERATURE The return water temperature should be maintained at not less than 40°C so as to avoid condensation on the boiler and return piping. Fitting a pipe thermo- Pipe Thermostat stat to the flow pipe of the gravity circuit and wiring it into the pump control will ensure rapid circulation of the hot water.
Thermostat Knob FLUE & WATER PIPE LOCATIONS 2 Water Pipe Flue Outlet Outlets Flue outlet to suit 152mm (6”) internal diameter flue pipe. Water connections 25mm (1”) B.S.P. Water Pipe Inlet Fig. 11 Primary Air Inlet STOVE DIMENSIONS Fig.12 Fig.13 WARNING: DO NOT OBSTRUCT PRIMARY AIR SUPPLY TO THE STOVE Note: Dimensions stated are in millimetres unless otherwise stated and may be subject to a slight +/- variation.
Fig.14 In the event where a stove is fitted to a central heat- ing system which is undersized in relation to the nominal heat output to boiler then the stove will operate satisfactorily but will be unable to achieve the nominal heat output to room as the thermostat- ic damper will shut off the air supply to prevent an overheat situation in the boiler.
Heat Model Class to Room to Water Index Fuel Output Net Efficiency Lismore HPB SF Stove 102.36 Wood 10.9 76.8 LIGHTING Before lighting the stove check with the installer, that the installation work and commissioning checks described previously have been carried out correctly and the chimney has been swept clean, is sound and free from any obstructions.
3mm separation between grate bars so that it can build up a bed of ash as it burns. The grate on the Lismore Stove can be changed Riddling Rod from a coal setting to wood burning setting.
Fig.20 SLOW BURNING Slow burning will cause the window glass to black- en and should not be used for a long period. It should only be done after the fire has been estab- lished and been funning at nominal output for a period of time.
VITREOUS ENAMEL CLEANING Fig. 22 General cleaning must be carried out when the stove is cool. If this stove is finished in a high gloss vitreous enamel, to keep the enamel in the best condition observe the following tips: 1. Wipe over daily with a soapy damp cloth, followed by a polish with a clean dry duster.
PROLONGED PERIODS OF NON USE (d) While awaiting the fire department watch for If the stove is to be left unused for a prolonged peri- ignition to adjacent combustibles from over- od of time then it should be given a thorough clean heated flue pipe or from embers or sparks to remove ash and unburned fuel residues.