Power Level "P" Representing the Power Level Currently Used by the Stove.
The Intended Temperature can be adjusted by pressing the Plus and Minus buttons With the thermometer in between them.
The heating power can be adjusted at any time by pressing the Plus and Minus buttons with the flame between them,
indicating power selection.
Five Power levels can be selected, 5 being the highest Heat Production.
By Pressing once one of the Buttons for Power Regulation, the selected power is indicated on the display. The initial power
at each start-up will correspond to the power level set before the last stop.
The Power Level the Stove is using can be different than the Power Level that is Selected.
That may happen when:
The Ambient Temperature is higher or equal to the temperature selected as Intended Temperature. In this case the stove
automatically selects Power Level 1
The Fumes Temperature is higher than the allowed temperature on the Selected Power Level. The controller for safety
reasons automatically chooses a lower Power Level.
Note! Observe the following recommendations when using the stove for the first few times:
The curing process of the paint is complete after the stove has been lit several times. During this curing process,
vapours and odours may be released during the first few times of use.
Start by using the stove at a medium power a few times so all mechanical parts can settle and the paint can cure.
This will increase the life of the stove.
Properly ventilate the room several times after and during the first times of use.
The first start-up of the pellet stove may take longer than usual. Because the Auger has not yet been filled, it takes
longer for the pellets to reach the combustion pot.
It may be that it takes too long for the pellet stove and an error message appears (Error1).
In this case, make sure the combustion pot is empty, press and hold
seconds to clear the alarm and restart the pellet stove using the 'ON/OFF' button.
8.1.5

Stop

The stop sequence of the stove is started by pressing the start/stop key for 3sec.
Until this phase has been completed, the display will show "Cooling Starting". The extractor will remain active until the fume
temperature drops adequately, to guarantee that all the material has been burnt.
8.1.6

Turning off the stove

The stove should only be disconnected from electrical power after having cooled down completely and the fan being inactive.
Make sure that the display indicates "Stove Off".
8.1.7

MENU

Use the menu to adjust various settings. Access this menu via SET
The following settings can be changed here:
8.1.8

Sub Menu "Set Date-Time"

Set the date and time here. Use the power buttons to switch
Use the temperature buttons to change the
Use SET to
save the changed setting.