Service Mode - Service Program Access

Available Service Mode Programs

List of available service programs:
Calibration - Incline calibration and treadmill calibration
Console Sel - Sets the treadmill base model
Display Test - Tests the display
Key Test - Tests the keypad

Accessing the Service Programs

Use these steps to access the Service Programs.
1. Set the ON/OFF switch to "ON" and remove the safety key from the console. Allow the
internal power supply to discharge, approximately 10 seconds.
2. While pressing the QUICK START and SPEED UP keys, simultaneously, replace the
safety key on the console. Continue to press the QUICK START and SPEED UP keys until
the display scrolls "SERVICE MODE". The main screen will display the upper software
version number.
3. Press the ENTER key, the display will read CALIBRATION. Use the UP/DWN arrows to
scroll between the test modes. Press the ENTER key to select the desired test. You can
press and hold the STOP key at any time to exit the SERVICE MODE program.

Calibration

4. Inc Limit will be displayed at the bottom of the display and the incline A/D number will be
displayed in the HEART RATE window. As the incline is raised or lowered the A/D number
should track the incline's movement.
5. The A/D number will be used to calibrate the incline.
Important
Do not change the A/D number at this point, if the incline requires calibration.
6. Press the ENTER key to enter the treadmill calibration mode.
Warning
During this program the running belt will be accelerated to the treadmill
maximum (12.0 mph) speed. Do not stand on the treadmill running belt during
this procedure.
7. This program must be performed after the upper PCA, the upper PCA software or the
lower PCA has been replaced and before the treadmill is placed into normal operation.
8. When the running belt stops the display will show the test results Pass or FAIL and return
to the normal user mode and the calibration process is complete.