Replacing the Drive Motor Brushes

Procedure

1. Set the treadmill on/off switch in the "off" position and remove the treadmill power cord from
the AC outlet.
2. Remove the treadmill hood.
3. Unsnap both brush covers (front and rear of the drive motor) from the drive motor.
4. Press inwards on the end of the one of brush springs and upwards to allow the brush spring to
disengage from the brush holder and slide out of the brush holder.
5. Disconnect the brush connector and remove the brush from the brush holder.
6. Slide the replacement brush into the brush holder and connect it to the brush connector on the
brush holder.
7. Slide the brush spring into the brush holder and then downwards and allow the brush spring to
slide into place and hook itself on the brush holder.
8. Repeat steps 4 to 7 on the remaining drive motor brush.
9. Snap the motor brush covers into place on the drive motor.
10. Replace the treadmill hood.
11. Verify the treadmill operation.