Install the media clamps correctly and clean their parts that are read. If this message still appears, con-
tact your authorized dealer.
RELATED LINKS
P. 27Setup of New Media
P. 60Setup of Registered Media

[The LAN cable is not connected.]

This message appears when the machine and a computer are not connected with a LAN cable.
Properly connect the LAN cable.
[Connection is requiring too much time. Manually setting the IP address will
improve the connection speed.]
This message appears when automatic IP address acquisition is enabled and the machine connects to a
network on which no DHCP server exists while this automatic acquisition is in progress.
Connect to a network on which a DHCP server exists or disable automatic IP address acquisition and set a
fixed IP address.

[There is ink that has expired.]

Ink has expired.
Replace with an ink pouch that is within its expiration date.
RELATED LINKS
P. 95Ink Pouch Replacement
[The temperature around the machine is too low. Adjust the room tempera-
ture.]
The temperature of the location where the machine is installed has fallen below the ambient temper-
ature at which the machine can operate.
This message appears when the temperature falls to 19°C (66.2°F) or lower during startup or operation
(when recovering from sleep mode).
Bring the installed location to a temperature at which operation is possible (20 to 30°C [68 to 86°F]) and
allow the machine to come to room temperature.
[The temperature around the machine is too high. Adjust the room tempera-
ture.]
The temperature of the location where the machine is installed has risen above the ambient tempera-
ture at which the machine can operate.
This message appears when the temperature rises to 36°C (96.8°F) or higher during startup or operation
(when recovering from sleep mode).
Bring the installed location to a temperature at which operation is possible (20 to 30°C [68 to 86°F]) and
allow the machine to come to room temperature.