Option 11C Mini - Nortel Meridian Meridian 1 Installation Manual

Dect messaging
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Page 54 of 60
Configuring the software

Option 11C Mini

P0989045
Standard 1.0 May 2002
Card slot number
The maximum system size is 9 cards, 5 slots in the Main Chassis (Cabinet 0)
and 4 slots in the Chassis Expander (Cabinet 1).
On Option 11C Mini systems, the card slots on Cabinet 0 are physically
labelled 0 – 5 and addressed by the DECT Messaging Server as slots 0 – 5.
The card slots on Cabinet 1 are physically labelled 7 – 10. However, the card
slots on Cabinet 1 are addressed by the DECT Messaging Server as
slots 17 – 20. See Table 7 on page 54.
Table 7
Slot numbering for Option 11C Mini
Cabinet
0
(Main Chassis)
1
(Chassis Expander)
System card slot
numbering
0 – 6
7 – 10
DECT card slot
numbering
0 – 6
Note: Slot 0 is
reserved for the system
controller card.
Slots 4-6 are reserved
for the digital line card.
17 – 20