6. SETTING THE FEED DOG
Check
1. Slideways the feed dog should be symmetrically
set in relation to the needle plate slot.
Adjustment
1. Remove the presser foot and holder.
2. Remove the needle plate.
3. Loosen the 2 screws tightening the feed dog.
4. Adjust the feed dog so that the teeth is centered in
the needle plate.
5. Retighten the screws.
6. Replace the needle plate and presser foot and
holder.
Settings