Remove the top cover of the CMUL.
1.
Remove the top cover by sliding it in the direction of the arrow while pushing
the latches on both sides of the CMUL (A in
To remove memory from the CMUU, proceed to step 2.
Figure 17-17     Removing the CMUL Top Cover
2.
Remove memory.
After opening the latches on both sides of the memory slot, remove the memory.
Note - To operate the system after removing memory, follow the instructions in
Memory Installation
Figure 17-18     Removing Memory
17.5
Installing the CMU and Memory
This section describes the procedures for installing memory and the CMU. To add a
CMUU, perform the procedure described in this section as well.
17.5.1
Installing Memory
This section describes the procedure for installing memory in the CMU.
450
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023