Intel® Server System M50FCP1UR System Integration and Service Guide
12. Return the lever to the original position (see Letter C).
13. Unlatch the tab on each corner of the processor carrier clip to release it from the heat sink (see Letter
D)
14. Lift the processor carrier clip up and away from the heat sink (see Letter E).
6.5.2

Processor Heat Sink Module (PHM) Assembly

The procedures described in the following sections must be followed in the order specified to assemble the
PHM and install it on to the server board. These instructions assume that the Thermal Interface Material
(TIM) is already applied to the bottom of the heat sink.
Figure 81. Installing Processor Carrier Clip onto Processor–Part 1
1. Position the Pin 1 indicator of the carrier clip with the Pin 1 indicator of the processor (See
2. With the processor still on its shipping tray, place the processor carrier clip over the processor.
66

Figure 80. Processor Carrier Clip Removal from PHM Assembly

Figure
81).