MAIN SUB
U1
01
Content
Battery abnormality
Detail
Backup SRAM battery voltage fall
Cause
Battery life
Battery circuit abnormality
Check and
Check that the battery voltage is about 2.5V
remedy
or above.
Check the battery circuit.
U2
00
Content
EEPROM read/write error (Controller)
Detail
EEPROM write error
Cause
EEPROM trouble
EEPROM is not initialized.
Controller PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly inserted.
remedy
Save the counter/adjustment values with the
DIAG simulation.
Use DIAG (SIM16) to cancel U2 trouble.
Replace the Controller PWB.
11
Content
Counter check sum error (Controller)
Detail
Counter data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
Controller PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly inserted.
remedy
Save the counter/adjustment values with the
DIAG simulation.
Use DIAG (SIM16) to cancel U2 trouble.
Replace the Controller PWB.
12
Content
Adjustment value check sum error
(Controller)
Detail
Adjustment data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
Controller PWB EEPROM access circuit
trouble
Check and
Check that EEPROM is properly inserted.
remedy
Save the counter/adjustment values with the
DIAG simulation.
Use DIAG (SIM16) to cancel U2 trouble.
Replace the Controller PWB.
90
Content
EEPROM read/write error (Controller)
Detail
PCU EEPROM write error
Cause
EEPROM trouble
EEPROM is not initialized.
PCU PWB EEPROM access circuit trouble
Check and
Check that EEPROM is properly inserted.
remedy
Save the counter/adjustment values with the
DIAG simulation.
Use DIAG (SIM16) to cancel U2 trouble.
Replace the Controller PWB.
91
Content
Memory check sum error (PCU)
Detail
PCU memory check sum error
Cause
EEPROM trouble
EEPROM is not initialized.
PCU PWB EEPROM access circuit trouble
Uninitialized E2PROM installed.
Check and
Check that EEPROM is properly inserted.
remedy
Save the counter/adjustment values with the
DIAG simulation.
Use DIAG (SIM16) to cancel U2 trouble.
Replace the Controller PWB.
MAIN SUB
U7
00
PF
00
AR-P350 TROUBLE CODES-7
Content
RIC communication trouble
Detail
RIC communication trouble
Communication cable test error after turning
on the power or exiting DIAG.
Cause
Disconnection of connector and harness
RTC control PWB trouble
Control PWB (Controller) trouble
Malfunction by noise
Check and
Canceled by turning OFF/ON the power.
remedy
Check connector and harness in the
communication line.
Content
RIC copy inhibit signal is received.
Detail
Copy inhibit command from RIM (host) is
received.
Cause
Judged by the host.
Check and
Inform to the host.
remedy