MAIN SUB
F1
80
Content
Finisher power abnormality
Detail
The 24V power is not supplied to the finisher
PWB.
Cause
Improper connection or disconnection of
connector and harness
Finisher control PWB trouble
Power unit trouble
Check and
Use DIAG (SIM3-2) to check the sensor.
remedy
87
Content
Finisher staple rotation motor trouble
Detail
Front staple rotation motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
F1
00
Content
Mail box communication trouble
Detail
Communication cable test error after turning
on the power or exiting from DIAG.
Communication error with the mail box.
Cause
Improper connection or disconnection of
connector and harness between the machine
and the mail box.
Mail box control PWB trouble
Control PWB (PCU) trouble
Malfunction by noises
Check and
Canceled by turning OFF/ON the power.
remedy
Check harness and connector in the
communication line.
Replace the mail box PWB or PCU PWB.
02
Content
Mail box transport motor abnormality
Detail
Transport motor trouble
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Mail box control PWB trouble
Check and
Use DIAG (SIM3-21) to check the transport
remedy
motor operation.
12
Content
Mail box gate trouble
Detail
Gate operation abnormality
Cause
Gate lock
Mail box control PWB trouble
Check and
Use DIAG (SIM3-21) to check the transport
remedy
gate operation.
80
Content
Finisher power abnormality
Detail
The 24V power is not supplied to the finisher
PWB.
Cause
Improper connection or disconnection of
connector and harness
Finisher control PWB trouble
Power unit trouble
Check and
Use DIAG (SIM3-20) to check the sensor
remedy
operation.
MAIN SUB
F1
03
06
10
11
15
19
20
AR-P350 TROUBLE CODES-3
Content
Console finisher paddle motor trouble
Detail
Paddle motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher slide motor trouble
Detail
Slide motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher stapler motor trouble
Detail
Stapler motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher bundle exit motor trouble
Detail
Bundle exit motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher lift motor trouble
Detail
Lift motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher front alignment motor
trouble
Detail
Front alignment motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.
Content
Console finisher rear alignment motor trouble
Detail
Rear alignment motor operation abnormality
Cause
Motor lock
Motor rpm abnormality
Overcurrent to the motor
Console finisher control PWB trouble
Check and
Use DIAG (SIM3-3) to check the motor
remedy
operation.