UNI-T UTS3000B/A Series User Manual page 69

Spectrum analyzer
Table of Contents

Advertisement

channel).
Press [Meas] > ACP to enter the following panel menu.
Meas/Setup:
Avg|Hold Num(On/Off): Press average time (on) to specify the average number of sweep to
calculating the measurement results. Sweep time range is from 1 to 999. User can change the average
time by using the numeric key, rotary knob, direction key, or touch the panel menu. Measured average
result will be displayed after the sweeping. Select (off) to turn off this measuring average function.
Avg Mode (Exponential/Repeat) : Switch between exponential and repetition average mode. When the
specified average time of sweep is reached, this average mode is used to determine the average
operation mode of the spectrum analyzer.
When the exponential average mode is selected, after a specified average time is reached, each
channel trace data is weighted exponentially, added to the previous average value and then take the
average. In the exponential average mode, the weight of the new data is larger than that of the old data,
which is conducive to track signals that change slowly. Measured average result will be displayed after
the sweeping.
When the repetition average mode is selected, after a specified average time is reached, all the previous
data will be delete and restart the sweeping.
Avg Type: Log-Pwr averaging is to average the logarithmic amplitude values (in dB) of the signal
envelope measured within a signal collection unit, the average detection type will change to video
detection. Power averaging is to average the power of the signal (the square of the amplitude),the
average detection type will change to RMS (power) detection.Voltage averaging is to average the
voltage values of the signal envelope measured in a signal collection unit, the average detection type will
changed to voltage detection, The voltage averaging is still a linear display.
Noise BW: Set the bandwidth of the main channel. The power is integral within the bandwidth of the
main channel (default value: 2MHz). User can change the carrier bandwidth by using the numeric key,
rotary knob, direction key, or touch the panel menu.
Integ BW: Set the frequency bandwidth of the adjacent channel. The adjacent channel bandwidth is
linked with the frequency bandwidth. Users can change the adjacent channel bandwidth by the numeric
key, rotary knob, direction key, or touch the panel menu.
Offset Freq: The center frequency spacing between the main channel and the adjacent channel.
Adjusting the channel spacing will adjust the distance among the previous channel, the next channel and
the main channel at the same time. Users can change the adjacent channel spacing by the numeric key,
rotary knob, direction key, or touch the panel menu.