4. Operation in Full Mode
4.1.3 Switching Users
Settings for users 0–9 can be configured in Full mode.
User 1–9
Configure advanced settings for each user needed. Settings for the users can then be saved.
User 0
User 0 is the default user. Thus, for this user you can adjust settings temporarily but not save them.
Setting information is cleared when you switch to users 1–9 or turn the lens off. User 0 is used if you perform an
escape operation. For details, see "4.1.17 Escape Operation." Selecting user 0 restores the default settings, except
for the auto and remote iris gain values and encoder output setting.
Switch to the desired user (0–9) from the Top screen.
Configure advanced settings for these users from the Menu screen. See "4.2 Configuration from the Menu Screen."
Initial Top Screen
[ ]
1
MENU
[ Basic ]
[Adj]
[ I-Gain ]
[Trk]OFF
[I-Tq]H
Fr1P
A
MENU
[ ] 1
MENU
MENU
[ Basic ]
[Adj]
[ I-Gain ]
[Trk]OFF
[I-Tq]H
Fr1P
A
[ ] 1
[ ] 2
MENU
[ ] 2
MENU
MENU
[ Basic ]
[Adj]
[ I-Gain ]
[Trk]OFF
[I-Tq]H
Fr1P
A
Options
Not supported
Although settings cannot be saved, they can be
Save Settings
changed temporarily.
Switching users or turning the lens off will restore
default values.
MENU
1
Press
.
The previous or default value is highlighted.
Press
.
2
The display starts blinking.
3
Press
or
Press left or right until you reach the desired value.
4
Press
.
The display changes from blinking to highlighted, indicating confirmation.
0
[ ] 1
.
(D)
1
2
3
4
Can be saved for each user
(D): Default value
or
E78
[
5
6
7
8
]
9