4. Operation in Full Mode
Specifying Iris Torque
Specify the desired level of torque in manual control of the iris ring.
First, switch to the user for whom the settings apply.
(For instructions, see "4.1.3 Switching Users" or "4.2.1 User Screen Settings: Switching Users.")
Initial Top Screen
[ ]
1
MENU
[ Basic ]
[Adj]
[ I-Gain ]
[Trk]OFF
[I-Tq]H
Fr1P
A
Iris Screen
[ ]
Iris
[ I-Gain ]
Torque:
High
Comp:
ON
[ ]
Iris
[ I-Gain ]
Torque:
High
Comp:
ON
[ ]
Iris
[ I-Gain ]
Torque:
Low
Comp:
ON
Options
Description
High torque
(D): Default value
MENU
Top
Important
1
Press
The display switches to the Iris screen.
2
Press
[Torque] is underlined.
The previous or default function is highlighted.
3
Press
Press left or right to switch the function to {High} or {Low}.
(D)
High
Low
Low torque
Iris
× 3
once and
three times.
twice.
or
.
[ ]
× 2
E130
or