3.2
Needle feed
18
Rule:
1. The needle bar should be laterally adjusted to flush with the presser
bar.
2. The wheel feed holder should be laterally adjusted to make the
clearance (A) approximately twice as wider than the clearance (B).
3. The feed movement of the needle should be set, so that, with
maximum stitch lengths, the needle leaves the throat plate close to
the backward edge of the stitch hole.
B
A
–
Loosen screw (1) and set the needle bar to the measure
(C) = 31mm as shown in the diagram. This procedure
accomplishes rule 1.
–
Set the adjustment rings (2) and tighten the screws (1).
c
1
2