3.6

Fastening Cycle Data

The BR-Series cordless tool stores data for 500 fastening cycles and 2 traces
and retrieved wirelessly through a STANLEY Controller, wirelessly using Alpha Toolbox on a computer, or with a Micro-USB
cable using the Alpha Toolbox Gateway program.
This data can be analyzed to determine root cause of failures when securing the rivet. Please contact STANLEY Assembly
Technologies or a STANLEY Assembly Technologies Authorized Distributor for information or assistance on STANLEY training
and data analysis.
This data can be retrieved manually or automatically. If an enterprise level client/server data collection software system
is employed all the data from all the tools in the facility can be collected into one database and displayed using the end
user's graphic reports software. The BR-Series cordless tool will need to remain in radio contact with an assigned STANLEY
Controller to facilitate data collection.
3.7

Tool Operation

Pair the tool to a STANLEY Controller. See 2.16 "Pairing Tool to Controller" on page 32. Read the STANLEY Controller in-
struction manual to understand programming of strategies to run the STANLEY BR-Series cordless tool.
A. Headlights on BR-Series Pistol Tools
There are two headlights located above the MFB, below the motor. The headlights are activated when the trigger switch is
depressed, and will automatically turn off after the programmed number of seconds after the trigger switch is released. If
the trigger switch remains depressed, the headlights will remain on.
NOTE: The headlights are for lighting the immediate work surface and are not intended to be used as a flashlight.
B.
Program Selection
The BR-Series cordless tool can have up to 16 Tasks programmed. Those Tasks are divided amongst up to 16 Jobs. The MFB
can be used to select Job/Task 1 and 2. If it is desired to select and run more than two programmed Jobs or Tasks the BR-Se-
ries cordless tool will need to remain in radio contact with an assigned STANLEY Controller. The BR-Series cordless tool can
also be equipped with the optional barcode scanner. This can also be used to select Jobs/Tasks.
The STANLEY Controllers have various means of changing the selected Job/Task such as inputs or barcode scans of product.
Read the STANLEY Controller manual to understand how to select a Job/Task.
C.
Tool Temperature
POTENTIAL BURN HAZARD
To Avoid Injury:
Wear thermal protective gloves when handling tools performing high duty cycles.