Multiple Function Button - Stanley BR Series Instruction Manual

Cordless tools
Table of Contents

Advertisement

3.2

Multiple Function Button

The multiple function button (MFB) is used to select direction of rotation for the output of the tool and to select different
modes. The first activation type is a quick press of the MFB called the TAP and the second activation is the HOLD which
requires the operator to hold the MFB for over .5 second to activate the assigned mode.
A. Multiple Function Button (MFB) Modes
The MFB Mode configures the multiple function button for handheld BR-Series Cordless Tool. Two of these modes may be
assigned at any one time as the MFB has two types of activation. The activations are TAP and HOLD. One mode may be
assigned to each type of activation. The activations can be configured to operate in any of the following modes:
FUNCTION
Disable
Job/Task Select
Job Reset
Reset Reject
40
The Multi-Function button does nothing
Pressing the button toggles between Job/Task 1 and Job/Task 2 and illuminates the appro-
priate orange indicator light [4].
Pressing the button casues the selected Job to be reset. This means that the rivet count is
reset and the tool, if disabled due to Error Proofing requirements, re-enables.
This function, when selected, will cause the tool to disable after a NOK fastening cycle. The
Reject Tone, when enabled, will sound. Pressing the button re-enables the tool indicating
the operator acknowledges the rejected fastening cycle and wishes to repair it.