3 Controlling Operation and Data Output with Ethernet
ABCDE,(0867,0708)(0867,0708)(1741,0673)(1741,0673)
 Output of the Symbol Quality Grade Information (ISO/IEC 15415)
• WebLink - Setup - Gear Icon - Advanced Settings - Symbol Quality - ISO/IEC 15415
1
Enable the Symbol Quality Grade Standard to output
The following is an example where all ISO/IEC 15415 Symbol Quality Grade parameters are
enabled.
2
If necessary, change the Separator Character.
In WebLink - Setup - Gear Icon - Advanced Settings - Symbol Quality - Global, enter a
character for Symbol Quality Separator. Below is an example where , is used as the Separa-
tor Character.
3
The Symbol Quality Grade is output appended to the Read result.
The following example shows Symbol Quality Grades appended to the Read string ABCDE.
ABCDE,C,A,C,C,C,A,A,A
 Additional Symbol Information That Can Be Appended
Additional
information
Symbol
Identifier
Decodes
per Trigger
Configura-
tion Data
Identifier
3 - 36
Setting to adjust
(WebLink - Advanced
Settings Menu)
I/O - Symbol Data Output
I/O - Decodes per Trigger
Output
I/O - Database Identifier
Output
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
Description
A (3 character) Symbol
Identifier indicating the
type of the read symbol is
put in front of its Read
string.
Outputs the number of
Good Read in Read Cycle
Outputs the Index Number
of the Configuration Data-
base used to get a Good
Read.
Example Output
(For Read string
Output Or-
ABCDE.) The de-
der
limiter character
is a , <comma>.
]dlABCDE
Put in front
of the Read
string
ABCDE,00002
1
ABCDE,DB01
2

Advertisement