Omron V430-F Series User Manual For Communication Settings page 127

Autofocus multicode reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

Appendices
Member Description
• INFO BITS
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Configuration Change Detection
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8.
• Device Status
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Error Code
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Counters
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Read Cycle Report
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Decode Cycle Report
MXL/SLC Input Assembly (Instance ID: 102) on page A - 8 - Same structure as
• Decode Data Length
Stores the number of characters in the Read string.
• Decode Data String
Stores the Read string. When additional information such as Print Quality Grading Standard is set, it
is stored following the Read string.
Assembly Memory Allocation
32 bit
A - 16
Member Name
InfoBits
Bit Run Mode
Bit Connection Faulted
Reserved
Reserved
Reserved
Configuration Change
Detection
Config Change Detect
Reserved
Reserved
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
Data Type
Bit Number
SINT
0
1
2
3 - 7
SINT
SINT
0
1 - 7
Data Length
Byte Offset
1 Byte
0
1 bit
1 bit
1 bit
5 bit
1 Byte
1
1 Byte
2
1 bit
7 bit
1 byte
3