Total Read Cycle Time
32 bit
Number of Decodes in Read
Cycle
Number of Decode Reports
RAW Input Data
Output Assembly (Instance ID: 197)
The Output Assembly can send several commands to the code reader.
Output Assembly Member Structure
COMMANDS
Member Description
• Commands
An explanation of commands that can be sent to the code reader.
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13 - 31
・Run Mode
Enables / Disables Read Cycle. Immediately after the code reader is started, Read Cycle will be en-
abled regardless of this command.
0 = Read Cycle Disabled. No trigger can be accepted. However, other commands can be executed. 1
= Enables Read Cycle.
・Trigger
Executes Read. The code reader recognizes this bit changing from 0 to 1 as the rising edge of the
trigger and its change from 1 to 0 as the falling edge of the trigger.
・Enable Matchcode
Enable / Disable the Matchcode function. Immediately after the code reader is started, the previously
saved setting is in effect regardless of this command.
0 = Disable Matchcode function.
1= Enable Matchcode function.
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
Member Name
Data Type
Member Name
Run Mode
Trigger
Enable Matchcode
Reset General Fault
Clear No Read Read Cycle Counter
Clear Mismatch Read Cycle Counter
Clear No Read Counter
Clear Trigger Counter
Clear Matchcode Counter
Clear Mismatch Counter
Output 1
Output 2
Output 3
Reserved
Bit Number
Data Length
0 - 15
2 byte
0 - 7
1 byte
0 - 7
1 byte
16 byte
Size (Bytes)
4
Total Size: 4 Bytes
Command
Appendices
Byte Offset
44 byte
A
A - 29