Omron V430-F Series User Manual For Communication Settings page 121

Autofocus multicode reader
Hide thumbs Also See for V430-F Series:
Table of Contents

Advertisement

Appendices
This bit becomes 1 when the Trigger bit from the Output Assembly is received. When the Trigger
bit is OFF, Trigger Acknowledged also becomes 0.
・Exposure Done
During exposure, this bit is set to 0.
When Exposure is done, this bit becomes 1.
・Decoding
During image processing, this bit is set to 1.
When image processing is done, this bit becomes 0.
・Data is Ready
When the data from Read Cycle Report and Data Cycle Report is confirmed, this bit becomes 1.
When the next Read starts, this bit becomes 0.
・Read Cycle Pass
On Good Read, this bit becomes 1.
When the next Read starts, this bit becomes 0.
・Read Cycle Fail
If the read cycle fails for any reason (No Read, Mismatch, etc,) this bit becomes 1. This bit will be
set to 0 at the start of a read cycle.
・General Fault
When a code reader Error occurs, this bit becomes 1. The user must resolve the problem by refer-
ing to the Fault Code field of the error code. After resolving the problem, the user must set "Reset
General fault" in the Output Assembly Control to 0.
・New Matchcode Acknowledged
This becomes 1 when the V430-F has accepted the Read string which was read by the next trigger
input as a new Master symbol.
When this bit becomes 1, the "Learn New Matchcode" bit in the Control field of the Output Assem-
bly must be set to 0.
・Matchcode Enabled
When Matchcode is Enabled, this bit becomes 1.
・Image Sensor Calibrating
This bit is set to 1 while the device is executing the following calibrations.
Exposure
Gain
Focus (1.2 Megapixel and 5 Megapixel cameras)
This bit is set to 0 when V430-F calibration is complete.
・Image Sensor Calibration Complete
This bit is set to 1 when the V430-F completes executing the following calibrations.
Exposure
Gain
Focus (1.2 Megapixel and 5 Megapixel cameras)
・Training
This bit is set to 1 while Training is in progress.
This bit is set to 0 when Training is complete.
・Training Complete
This bit is set to 1 when Training is complete. If an error occurs, it is output by Fault Code area.
・Optimizing
This bit is set to 1 while Optimization is in progress.
This bit is set to 0 when Optimization is complete.
・Optimization Complete
This bit is set to 1 when Optimization processing is complete. If an error occurs, it is output by Fault
Code area.
A - 10
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings

Advertisement

Table of Contents
loading

Table of Contents