5 Controlling Operation and Data Output with RS-232C
 Point-to-Point
It is a basic RS-232C communication protocol that does not control communication by a control
code.
External device
Character notation
Code Reader
 Point-to-Point with XOn/XOff
With this protocol, if the free space of the Receive buffer on the side receiving data becomes small,
it sends XOff (Hex:13) to the Data Transmit side to request transmission interrupt. When it has
enough free space again, it sends XOn (Hex:11) to the Data Transmit side to request Re-transmit.
External device
Request transmission interrupt
Character notation
Code Reader
 ACK/NAK
ACK/NAK Control Codes are an RS-232C communication protocol for confirming communication.
When data is received, an ACK (Hex:06) response is sent to the device that sent the data. When
data is not successfully received, a NAK (Hex:15) response is sent to the device that sent the data.
If the device that sent the data receives a NAK response, it re-transmits its data.
When the data was successfully received:
External device
Character notation
Code Reader
When the data was not received:
External device
Character notatiion
Code Reader
5 - 6
Serial Trigger command
<
>
Hex notation
3C
20
3E
In Read Cycle
Character notation
Hex notation
Serial Trigger command
XOff
<
Hex notation
13
3C
20
If XOff is received, data is not output until XOn is received.
Serial Trigger command
<
>
Hex notation
3C
20
3E
ACK response
Character notation
ACK
Hex notation
06
Serial Trigger command
<
>
Hex notatiion
3C
20
3E
ACK response
Character notatiion
ACK
Hex notatiion
06
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
Read result
1
2
3
4
5
CR
LF
31
32
33
34
35
0D
0A
Request re-transmit
>
3E
In Read Cycle
Character notation
Hex notation
In Read Cycle
Read result
1
2
3
4
5
31
32
33
34
35
In Read Cycle
Read result
1
2
3
4
5
31
32
33
34
35
XOn
11
Read result
1
2
3
4
5
CR
LF
31
32
33
34
35
0D
0A
ACK response
ACK
06
CR
LF
0D
0A
NAK response
NAK
15
Read result
CR
LF
1
2
3
4
5
0D
0A
31
32
33
34
35
When NAK is received, previous Output data is re-sent.
ACK response
ACK
06
CR
LF
0D
0A

Advertisement

Table of Contents
loading

Table of Contents