A-2 EtherNet/IP Specifications
A-2-1
Assembly Memory Allocation
An explanation of the memory allocation of each Input Assembly (V430-F → PLC) and each Output
Assembly (PLC → V430-F).
Small Input Assembly (Instance ID: 100)
It is a compact, lightweight input assembly. It is designed to hold 64 bytes of information in the Read
result. When reading multiple symbols, the Read strings are output delimited by Separator Characters.
The following table lists the Member Structure of the Small Input Assembly
Small Input Assembly Member Structure
USER-DEFINED TAG ECHO
COMMAND ECHO
OUTPUT CONTROL ECHO
READ CYCLE SEQUENCE COUNTER
DECODE DATA LENGTH
DECODE DATA STRING
Member Description
• User-Defined Tag Echo
Returns the value set in the User-Defined Tag field of the Output Assembly (Legacy).
• Command Echo
Returns the value set in the Command field of the Output Assembly (Legacy).
• Output Control Echo
Returns the value set in the External Output field of the Output Assembly (Legacy).
• Read Cycle Sequence Counter
Stores the current Read Cycle Count.
• Decode Data Length
Stores the number of characters in the Read string.
• Decode Data String
Stores the Read string. When additional information such as Print Quality Grading Standard is set, it
is stored following the Read string.
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
Member Name
Appendices
Size (Bytes)
4
4
4
4
4
64
Total Size: 84 Bytes