Precautions for Correct Use
In perform a hardware reset in this manner, it must be executed within 60 seconds of the read-
er being started by either its power supply being turned on or the reader being reset.
Connecting incorrect pins can cause serious damage to the equipment.
 How to use
1
Verify the location of Pin 3 (DEFAULT) and Pin 7 (GROUND) on the connector.
2
Supply power to the code reader.
3
Indicator light PWR (Green) lights up.
4
After a while, the indicator lights LINK (Orange), MODE (Orange), TRIG (Orange) will light up
once and the code reader will start up.
5
Within 60 seconds of this indication of the code reader starting up, short-circuit (connect) Pin 3
and Pin 7.
6
Within 3 seconds after doing that, disconnect and then re-connect Pin 3 and Pin 7 (short-circuit
them again).
7
The code reader resets. After it restarts this time, disconnect Pin 3 and Pin 7.
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
2 Controlling Operation and Data Output with Parallel