Siemens SIMATIC RF200 System Manual page 99

Rfid systems
Hide thumbs Also See for SIMATIC RF200:
Table of Contents

Advertisement

Index
Object
Subindex
name
0x5A
Reader
0x00
status
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01
Length
Access Parameter
in bytes
name
18
r
-
4
r
Time since
startup
1
r
Tags in the
field
1
r
Antenna ctatus Status of the antenna:
4
r
Tag changes
1
r
Line driver
Revision
1
r
Reader FZB
1
r
Reader ABZ
1
r
Reader CFZ
1
r
Reader SFZ
1
r
Reader
CRCFZ
1
r
Reader BSTAT Number of command repetitions
1
r
Reader FZ
A.2 Overview of the service data
Description
Can only be read out entirely, only subindex 0
possible.
Operating time of the reader since startup
Number of transponders located in the field
Here, only 1 transponder is permitted.
0: Unknown
1: Antenna on
2: Antenna off
Number of transponders that have passed
through the field since the reader was turned on
Version of the physical IO-Link driver block
HF field, error counter passive (for example
interference pulses)
Is reset when read out.
HF protocol error, abort counter
Is reset when read out.
HF protocol error, code error counter
Is reset when read out.
HF protocol error, signature error counter
Is reset when read out.
HF protocol error, CRC error counter
Is reset when read out.
Is reset when read out.
Error count
Appendix
99