Program code
>I
;
SPB
enda;
SPA
ende;
//Read next transponder
enda: U
"VKE1";
=
"Once_flag";
L
0;
T
"PAA_CMD";
T
"lwa";
T
"PAA_Adr_L";
T
"FC1Daten".dbadresse;
SPA
ende;
// Troubleshooting
erro: L
"FC1Daten".fehler1;
L
1;
+I
;
T
"FC1Daten".fehler1;
L
"PAA_Adr_L";
T
"FC1Daten".err_dbadresse;
L
"PAA_CMD";
T
"FC1Daten".err_cmd;
L
"PAE_Status";
T
"FC1Daten".err_Status;
L
"PAE_Error_RFID";
T
"FC1Daten".err_ErrorRFID;
L
0;
T
"FC1Daten".dbadresse;
T
"lwa";
T
"PAA_Adr_L";
T
"PAA_CMD";
U
"VKE1";
=
"Once_flag";
ende: BE
;
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01
Commissioning and parameter assignment
//Comments
(MDS D124 = 112 bytes = 6F hex)
// => End when end address reached
// => Continue reading in next cycle
// When all data has been read
// End reading of the transponder
// => then deleted address etc.
//
"
//
"
// => wait for new transponder
// Count errors
// and end reading
// Data that led to error
// save
//
"
//
"
//
"
//
"
//
"
//
"
// Delete addresses/memory bits/memory
//
"
//
"
//
"
//
"
// End reading