Commissioning and parameter assignment
5.5 Application example
Table 5- 2
Shared data block
Program code
DATA_BLOCK "FC1Daten"
TITLE =ScanUserData
AUTHOR : IASCCI
FAMILY : RFID
NAME : IOLink
VERSION : 1.0
STRUCT
data
: ARRAY
fehler1
: WORD
dbadresse
: Byte
err_dbadresse : BYTE ;
err_cmd
: BYTE ;
err_Status : BYTE ;
err_ErrorRFID : BYTE ;
END_STRUCT ;
BEGIN
fehler1
:= W#16#0;
dbadresse
:= B#16#0;
err_dbadresse := B#16#0;
err_cmd
:= B#16#0;
err_Status
:= B#16#0;
err_ErrorRFID := B#16#0;
END_DATA_BLOCK
74
[1 .. 112 ] OF BYTE;
:= W#16#0;
:= B#16#0;
// Memory for "error" count
// Memory for "dbadresse"
//Comments
// Memory for "data"
// Memory for "error" count
// Memory for "dbadresse"
// Memory address if error occurs
// memory Command if error occurs
// Memory status if error occurs
// memory Error_RFID if error occurs
// Memory address if error occurs
// memory Command if error occurs
// Memory status if error occurs
// memory Error_RFID if error occurs