Commissioning and parameter assignment
5.2 Parameter assignment of the IO-Link system
Tag status (index 91)
- UID byte 0
- UID byte 1
- UID byte 2
- UID byte 3
- UID byte 4
- UID byte 5
- UID byte 6
- UID byte 7
- Tag type
- Chip version
- Memory size in bytes
- Lock status
- Memory block size
- Number of blocks
UID history (index 92)
- Last UID
- Second UID
- Third UID
- Fourth UID
- Fifth UID
66
0xe0
0x04
0x01
0x00
0x01
0x9c
0xe9
0x1c
MDS D1xx,
I-Code SLI (NXP)
0x01
112
0
4
28
0xe0040100019ce91c
0x00
0x00
0x00
0x00
Byte 0 of the unique identifier of the
transponder
Byte 1 of the unique identifier of the
transponder
Byte 2 of the unique identifier of the
transponder
Byte 3 of the unique identifier of the
transponder
Byte 4 of the unique identifier of the
transponder
Byte 5 of the unique identifier of the
transponder
Byte 6 of the unique identifier of the
transponder
Byte 7 of the unique identifier of the
transponder
Transponder name /
name of the chip / (manufacturer)
Version of the chip
Memory size of the chip in bytes
Disabled blocks on the chip
Size of the memory blocks of the chip
Number of memory blocks of the chip
Transponder history
Transponder history
Transponder history
Transponder history
Transponder history
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01