Planning an RF200 IO-Link system
4.2 Field data of transponders and readers
Table 4- 4
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D424
MDS D426
MDS D428
MDS D460
26
SIMATIC RF260R field data
Length of the
transmission window (L)
120
60
80
120
60
120
120
80
80
80
100
50
50
Operating distance (S
)
a
2 ... 110
2 ... 80
2 ... 75
2 ... 80
2 ... 40
2 ... 120
2 ... 100
2 ... 75
2 ... 60
2 ... 60
2 ... 50
2 ... 40
2 ... 40
System Manual, 03/2012, C79000-G8976-C276-01
Limit distance (S
)
g
130
85
100
110
45
135
120
90
70
70
60
45
45