Error code
Error description
(hex)
5100
General problem
with the power
supply
6000
Firmware error
6320
Parameter
assignment error
8C00
Reset Device
The device status has the same meaning as the RFID error code.
1)
Note
You can display these event messages using S7-PCT or read them out using the
"IOL_CALL" function block. You can only reset event messages using S7 PCT or the
"IOL_CALL" function.
The event messages cannot be reset by "antenna off" or "move transponder out of field" as
is possible with the RFID errors (compare section "Diagnostics (Page 81)").
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01
Device status
)
1
RFID error code (hex) 11
RFID error code (hex) 14
RFID error code (hex) 15
RFID error code (hex) 14
Event type
Causes of errors
Error
Hardware fault:
coming/
Under/overvoltage
going
Check the power supply.
Error
The firmware has detected an internal error
coming/
(system).
going
For example illogical status or watchdog etc.
Error
Parameter assignment error:
coming/
Bad parameter
going
Error
Serious system error, watchdog:
coming/
Cycle power
going