7. Assemble the two inner rails (one on each side) to the switch using (6) #8-32 x
5/16 Phillips pan-head screws, and #8 flat washer as shown in Figure 2–9.
Figure 2–9: Assembling the inner rails
CAUTION: Do not use any other screws other than the six that are provided. Use of
any longer lengths can cause damage to internal components of the switch. Before
tightening screws, make sure that the rails are centered to the overall height of the
switch.
8. Insert the switch with the attached inner rails into the outer rails.
9. Install the two remaining M5 Torx screws to complete the installation.
10. Go to the next section, "Connecting AC Power" for steps on applying power to the
switch.
NOTE: Do not connect the switch to the network until the IP address is correctly set. For
instructions on how to set the IP address, see "Configuring SAN Switch 2/32 Network
Addressing," later in this chapter.