Fan Assemblies

The three fan assemblies are hot-swappable if replaced one at a time. The fan
assemblies are identical and fit into any fan assembly slot, see Figure 3–4.
1
1
Power supply #2
2
Fan assembly containing fans 5,6
Figure 3–4: Power supplies and fan assemblies locations
Each fan assembly contains two fans, identified by Fabric OS as follows (viewing the
switch from the non-port side assembly on the right contains fans #1 and #2.
The fan assembly in the center contains fans #3 and #4.
The fan assembly on the left contains fans #5 and #6.
Any of the following methods can be used to determine whether a fan assembly
requires replacing:
Check the Fan Failure LED on the face of the fan assembly
Enter the fanshow command
In Web Tools, click the Fan Status icon

Motherboard Assembly

The switch must be powered off and removed from the fabric (and possibly from the
cabinet) to replace the motherboard assembly. To determine whether the motherboard
assembly requires replacing, first check the Switch Power/Status and Port Status
LEDs. Next, run diagnostics (refer to the hp StorageWorks Fabric OS Version
3.0.x/4.0.x Procedures Guide). If the motherboard assembly appears to require
replacing, contact your switch supplier.
SAN switch 2/32 version 4.0.x installation guide
2
3
3
4
5
Managing the SAN Switch 2/32
4
5
SHR-2580A
Fan assembly containing fans 3,4
Fan assembly containing fans 1,2
Power supply #1
3–15